Print This Page
Grinder Pumps
Alarm Panels
Lateral Kits
Grinder Pump & Parts Price Lists
Grinder Pump Specifications
Grinder Pump Performance Curve
Low Pressure Sewer System Design
E/One Mapping  
E/One Finance  

 

Indoor Station | IH091

Once again, we're going places. A place where other grinder pumps just can't go. Inside. With an indoor unit that installs in a matter of minutes, has a clean design and seems at home with other household appliances.

Grinder Pump station for low pressure sewer system - installed inside the home

Operational Information

Motor

1 HP, 1725 rpm, high torque, capacitor start, thermally protected, 240 or 120 volt, 60 hertz, 1 phase

Inlet Connections
4" PVC socket weld

Discharge Connections
Pump discharge terminates in 1-1/4" NPT female thread. Can easily be adapted to 1-1/4" PVC pipe or any other material required by local codes.


Discharge*

15 gpm at 0 psig
11 gpm at 40 psig
7.8 gpm at 80 psig


Overload Capacity

Maximum pressure that the pump can generate is limited by motor characteristics to a value well below the rating of the piping and appurtenances. Automatic reset feature does not require manual operation following overload.

US and foreign patents issued and pending.

*Discharge data includes loss through check valve, which is minimal.

**CSA certification applies only to grinder pumps bearing the "C" in the model number.