Print This Page
Grinder Pumps
Alarm Panels
Lateral Kits
Grinder Pump & Parts Price Lists
Grinder Pump Specifications
Grinder Pump Performance Curve
Low Pressure Sewer System Design  
E/One Mapping  
E/One Finance

 

E/One Sentry Alarm PanelPreSTAT Package

E/One Sentry PreSTAT provides advance warning of pending service needs by monitoring major operating conditions. A Trouble indication is provided when these conditions fall outside of normal ranges, although the grinder pump station may continue to operate.

E/One Sewer Systems :: E/One Sentry Panel for Grinder Pumps

The E/One PreSTAT feature provides predictive status monitoring of:

  • AC input voltage — if input voltage falls below 88 percent or rises above 112 percent of normal line voltage, a Trouble indication is provided
  • Amperage — if amperage exceeds preset limits, a Trouble indication is provided
  • Pump run time — if the pump operates for extended periods (adjustable), a Trouble indication is provided

PreSTAT offers a new standard of reliable and uninterrupted service through better asset management. Several option packages for the E/One Sentry panel are available — Basic, Protect, Protect Plus and PreSTAT.

"PreSTAT" Option Package

• Programmable auto-dialier
• Predictive status display module
• Pre-alarm indication for major operating parameters
• Alarm indications for major operating parameters
• Audible and visual alarm
• NEMA 4X-rated enclosure with padlock
• Hour meter, cycle counter and alarm delay
• LCD display and user-friendly interface
• Inner cover (dead front)
• Circuit breakers, 240 VAC service
• Terminal blocks and grounding lugs
• Contact group (dry, powered and Remote Sentry)
• Safety front — authorized personnel only when locked
• Conformal-coated alarm board (both sides)

Drawings & Brochure

E/One Sentry brochure (PDF)

E/One Sentry drawings, PreSTAT Package (PDF)

E/One Sentry drawings, PreSTAT Package (Zipped DXF)