Generator Condition Monitor - Explosionproof Gen-Tags Generator Gas Analyzer Portable Hydrogen Gas Analyzer Generator Gas Dryer Generator Gas Manifold Gas Station Generator Condition Monitor - Air-Cooled Apparatus Generator Overheat Monitoring

 

Generator Gas Analyzer (GGA)


Purity, efficiency, and safety

E/One Generator Gas
Analyzer Systems
E/One's Generator Gas Analyzer for Hydrogen-Cooled Generators, available in stand-alone and portable configurations, or as part of a larger moniroting and control system

E/One's Generator Gas Analyzer (GGA) for hydrogen-cooled generators is a triple-range sensor/analyzer that provides continuous monitoring of gas purity during all phases of generator operation.

We've taken a proven monitoring principle — thermal conductivity — and improved upon it. The result of E/One's development work is an extremely accurate, robust and stable system that eliminates the issues of drift and need for frequent recalibration seen in other thermal conductivity systems.

E/One supplies GGA systems in a range of configurations, from stand-alone sensor/analyzers and retrofit "drop-in" replacement systems, to comprehensive hydrogen control cabinets that monitor gas purity, provide continuous monitoring of case and differential pressures and interact with plant control systems to assure the highest level of generator efficiency.
Portable Gas Analyzer - E/One's Generator Gas Analyzer for Hydrogen-Cooled Generators in a portable configuration for non-hazardous areas

E/One also offers a portable hydrogen gas analyzer (PGA). The PGA incorporates the same sensor/analyzer and system electronics found in E/One's other gas purity systems. The PGA is specifically intended for use in non-hazardous environments and/or as an emergency backup if a power plant's primary gas purity monitoring system is compromised.

E/One's hydrogen gas monitor is also available as part of the E/One Gas Station, which lets power plants combine several E/One generator monitoring and control systems onto one skid.

Available in North America, E/One now offers best-in-class thermal conductivity and vibrating element technology with E/One’s GGA and Yokogawa Corporation of America’s (YCA) GD402. The E/One-YCA alliance brings together industry leaders focused on plant-level relationships and a wide range of generator applications. With E/One’s GGA and YCA’s GD402, operators are provided with options in continuous monitoring of gas purity throughout all phases of generator operation.

Generator Gas Analyzer Features and Benefits

  • Increased generator efficiency and safety
  • Microprocessor controlled
  • Flameproof, explosion-proof, and intrinsically safe designs
  • Custom configurations to meet site-specific requirements
  • Suitable for new and retrofit applications

Generator Gas Analyzer Specifications

 
GGA/PGA
GD402
 
MEASUREMENT CHARACTERISTICS
Technology Principle Thermal Conductivity Vibrating Element (VBE)
Case Purity 70% to 100% H2 in Air 80% to 100% H2 in Air
Purge 0 to 100% H2 in CO2 0 to 100% H2 in CO2
0 to 100% Air in CO2 0 to 100% Air in CO2
Flow Rate 100 to 700 cc/min 100 to 700 cc/min
(100 nominal for GGA) (100 nominal)
 
ELECTRICAL CHARACTERISTICS
Power - Input Voltage 115/230 VAC 100/240 VAC
Input Frequency 50/60 Hz 50/60 Hz
Output Signal 4-20 mA current output, (2) 4-20 mA current output,
self-powered self-powered
(and BNC for PGA)
Output, Relays 30V/1.0 A DC, 120V/0.5 A AC 30V/30A DC, 250V/0.3 A AC
Alarm, NO and NC 125V/0.005 A resistive DC 125V/0.005 A resistive DC
Warning, NO and NC Maintenance, NO and NC
Trouble, NO and NC Fail, NC
Normal, NO and NC
 
MECHANICAL CHARACTERISTICS
Overall Dimensions GGA based on configuration Based on configuration
PGA 16.5"W x 9"D x 8.5"H
(42 mm x 23 mm x 22 mm)
Enclosure Dimensions (GGA only)
System Electronics Enclosure 11" x 12" x 9.25"
Sensor Cell Enclosure 8" x 10" x 6.25"
Display Enclosure 0.5" x 8.5" x 6.25" or panel
Valve Panel (optional) mounted per requirement
Weight GGA based on configuration Based on configuration
PGA 14 lbs. (6.5 Kg)
Temperature GGA 32-158 F (0-70 C), optional
PGA 32 to 125 F (0 to 52 C) 10-140 F (-10 to 60 C)
Relative Humidity 0-95% 5-95%
Area Classification GGA Class 1, Division 1, Class 1, Division 1, Group B, C, D
Group B; Class 1, Zone 2, Hydrogen
PGA - None
Gas Pressure 100 psi maximum 70 psi maximum
Gas Connections 1/4" female NPT 1/4" female NPT